How to Select a Flow Meter for Water and Wastewater Applications

Water and wastewater systems include very different measurement duties: raw-water intake, potable-water transfer, desalination, cooling water, treated effluent, sewage, sludge, chemical dosing and plant utilities. A single flowmeter technology should not be applied to all of them. The right choice depends on the electrical conductivity of the liquid, solids content, pipe size, flow range, pressure, temperature, required accuracy, chemical compatibility and whether the process needs volumetric flow, direct mass flow or another variable such as density. Within Yokogawa’s portfolio, magnetic flowmeters are the main starting point for conductive water-based streams, while Coriolis and vortex technologies solve more specialized dosing and utility applications.

APPLICATION GUIDEYokogawa

Why magneticBy applicationWhich meterDatasheet checklist

Request a Yokogawa Flowmeter Recommendation

Your process, equipment or measurement requirement.

01 TECHNOLOGY

Why Magnetic Flowmeters Are Common in Water and Wastewater

Magnetic flowmeters measure volumetric flow in conductive liquids without a mechanical obstruction in the measuring tube. This makes them well suited to many water and wastewater services because there are no moving parts in the flow path and permanent pressure loss is low. Yokogawa positions ADMAG AXW specifically for water supply, sewage and general industrial lines, with sizes from 25 to 1,800 mm. ADMAG AXG covers smaller process sizes and more demanding process-industry applications, including water and wastewater where its materials, diagnostics or size range make it the better fit.

Magnetic technology still has application limits. The pipe must remain full, the fluid must meet the conductivity requirement of the selected meter, and liner and electrode materials must suit the process. Entrained gas, heavy coating, severe abrasion or highly variable solids loading can affect the selection. For this reason, a wastewater application should be described by its actual medium and operating conditions rather than simply labelled ‘wastewater’.

02 BY APPLICATION

Six Water Duties, Six Different Selection Questions

Describe your application

Raw Water and Potable Water

Raw-water and potable-water lines are often strong magnetic-flow applications when conductivity is adequate. Large transmission lines can favor AXW because the family extends to very large diameters, while plant-level or smaller process connections may fall into either AXG or AXW depending on size and project specification. Important inputs include min/normal/max flow, seasonal demand, pressure class, whether the meter may be submerged, required drinking-water approvals, and the available straight-run and installation arrangement. Where a meter is replacing an older magnetic flowmeter, flange dimensions, converter arrangement and existing cabling should be included in the review.

Wastewater, Sewage and Treated Effluent

Wastewater and sewage frequently contain suspended solids, making a full-bore electromagnetic meter attractive where the liquid is conductive and the selected materials are appropriate. AXW is explicitly positioned by Yokogawa for sewage and drainage applications. The selection should still consider solids size and concentration, grease or coating tendency, abrasion, chemical cleaning and whether the meter is installed in a wet well, buried chamber or other environment that affects enclosure or submersible requirements. For treated effluent, the fluid may be cleaner but conductivity can become more important if treatment significantly reduces dissolved ions.

Sludge and Solids-Bearing Streams

Sludge is not one uniform fluid. Primary sludge, activated sludge, digested sludge and dewatered sludge can have very different solids content, rheology and coating behavior. Magnetic flow measurement is often considered because the meter has no moving obstruction in the bore, but the application must be checked for conductivity, abrasion, adhesion and whether the pipe remains completely full. Very difficult high-solids or strongly adhesive media should be treated as a dedicated application-engineering problem rather than an automatic AXG or AXW selection.

Desalination and High-Salinity Water

Desalination plants include seawater intake, pretreatment, reverse-osmosis feed, permeate, brine, remineralization and chemical-dosing services. Magnetic flowmeters can be relevant to many conductive liquid streams, but salinity and chemical composition make wetted-material selection important. The process description should therefore specify the stage of the plant, chloride level or chemical composition where relevant, pressure and temperature, rather than using the broad term ‘desalination water’. High-pressure RO feed may also have different pressure-class requirements from conventional treatment lines.

Chemical Dosing: When Coriolis May Be More Appropriate

A small chemical-dosing line can have a different objective from a large water-transfer line. If the process requires direct mass flow, density or highly accurate batch quantities, ROTAMASS Coriolis may be a better starting point than a magnetic meter, provided the chemical, flow range and pressure-drop requirements suit the technology. Magnetic flow can still be appropriate for conductive dosing chemicals, especially where the process favors a full-bore design. The selection should be made from the dosing objective rather than from line size alone.

Cooling Water and Plant Utilities

Cooling-water circuits are normally conductive-liquid applications and can be strong candidates for magnetic measurement. However, water-treatment plants also use steam, compressed air and gases as utilities. Those services should not be pushed into the magnetic-flow category. Yokogawa vortex flowmeters can measure suitable liquids, gases, saturated steam and superheated steam and are therefore relevant to utility systems outside the main water stream. The Magnetic vs Coriolis vs Vortex Flow Meter comparison can help separate these technology choices before product sizing begins.

03 STARTING POINT

Which Yokogawa Magnetic Flowmeter Fits the Application?

APPLICATION Likely starting point Why
Large water transmission / sewage pipeline ADMAG AXW Large size range; water and sewage positioning
General plant water / wastewater AXW or AXG Select by size, materials, diagnostics and project standard
Small process water / chemical line ADMAG AXG Smaller size range and process-industry positioning
Conductive slurry / solids-bearing stream Application review; often AXG/AXW candidate Check abrasion, solids, conductivity and coating
Chemical dosing requiring direct mass flow ROTAMASS Coriolis Direct mass flow and density capability
Steam / gas utility Vortex Magnetic flow is not applicable to gas or steam

For a deeper magnetic-family comparison, use the AXG vs AXW comparison. If the measurement principle itself has not yet been decided, the Yokogawa Magnetic Flow Meter Selection Guide should be the first supporting page.

04 CHECKLIST

Water and Wastewater Flowmeter Datasheet Checklist

  • Application: raw water, potable water, wastewater, sludge, dosing, cooling water, desalination or other
  • Exact liquid composition
  • Conductivity if known
  • Solids concentration, particle size, abrasion or coating risk
  • Pipe size and schedule
  • Minimum, normal and maximum flow
  • Operating and design pressure
  • Operating and design temperature
  • Required liner and electrode materials
  • Buried, flooded, submersible or indoor installation
  • Required accuracy and turndown
  • Output and communication protocol
  • Drinking-water, hazardous-area or other project approvals
  • Existing meter and flange dimensions for replacement projects

Request a Yokogawa Flowmeter Recommendation

Send Tomarok the application, liquid composition, conductivity if known, solids information, pipe size, flow range, pressure, temperature and installation conditions. Tomarok can use the data to determine whether magnetic measurement is the correct starting technology and whether AXG, AXW, Coriolis or vortex should be evaluated next. This avoids selecting a flowmeter only from industry labels and creates a clearer route from process data to a technically appropriate quotation.

NEWSLETTER

Project news, engineering insights and partner updates — a few times a year, no noise.

Download our company brochure

Enter your work email to get instant access to the Tomarok company brochure. We will also email you the download link.

Work email *

We use your email to send you the brochure. Read our Privacy Policy.